Home » Sick |
Sick UM30-213118, 6036923
![]() |
|
Sick Ultrasonic sensors UM30 / UM30-2
-
Mechanics/electronics
Supply voltage Vs DC 9 V ... 30 V 1) 2) Power consumption ≤ 2.4 W 3) Initialization time < 300 ms Design Cylindrical Housing material Metal (nickel-plated brass, PBT)
Ultrasonic transducer: polyurethane foam, glass epoxy resin
Thread size M30 x 1.5 Connection type Male connector, M12, 5-pin Indication LED display, 2 x LED Weight 150 g Sending axis Straight Dimensions (W x H x D) 30 mm x 30 mm x 84 mm Enclosure rating IP65 / IP67 Protection class III - 1) Limit values, reverse-polarity protected Operation in short-circuit protected network: max. 8 A, class 2.
- 2) 15 V ... 30 V when using the analog voltage output.
- 3) Without load.
-
Performance
Operating range, limiting range 200 mm ... 1,300 mm, 2,000 mm Target Natural objects Resolution ≥ 0.18 mm Repeatability ± 0.15 % 1) Accuracy ± 1 % 2) 3) Temperature compensation ✔ Response time 92 ms 4) Switching frequency 8 Hz Output time 23 ms Ultrasonic frequency (typical) 200 kHz Detection area (typical) See diagrams Additional function Adjustable operating modes: Switching point (DtO) / Switching window/Background (ObSB), teach-in of digital output, set levels of digital outputs, invertable digital output, set on delay digital output, teach-in of analog output, scaling of analog outputs, Invertable analog output, automatic selection of analog current or voltage output, synchronization of up to 50 sensors, multiplexing: no cross talk of up to 50 sensors, adjustable measurement filters: Measured value filters/Filter strength/Foreground suppression/Detection area/Sensitivity and sound beam, Display (can be deactivated), reset to factory default - 1) In relation to the current measured value, minimum value ≥ resolution.
- 2) Referring to current measurement value.
- 3) Temperature compensation can be switched off, without temperature compensation: 0.17 % / K.
- 4) Subsequent smoothing of the analog output, depending on the application, may increase the response time by up to 200 %.
-
Interfaces
Digital output Number 1 1) Type PNP Maximum output current IA ≤ 200 mA Analog output Number 1 Type Current output / voltage output Function Automatic selection of analog current or voltage output dependent on load Current 4 mA ... 20 mA, ≤ 500 Ω 2) Voltage 0 V ... 10 V, ≥ 100,000 Ω Resolution 12 bit Multifunctional input (MF) 1 x MF Hysteresis 20 mm - 1) PNP: HIGH = VS - (< 2 V) / LOW = 0 V.
- 2) For 4 mA ... 20 mA and Vs ≤ 20 V max. load ≤ 100 Ω.
-
Ambient data
Ambient temperature, operation –25 °C ... +70 °C Ambient temperature, storage –40 °C ... +85 °C
-
Classifications
ECl@ss 5.0 27270804 ECl@ss 5.1.4 27270804 ECl@ss 6.0 27270804 ECl@ss 6.2 27270804 ECl@ss 7.0 27270804 ECl@ss 8.0 27270804 ECl@ss 8.1 27270804 ECl@ss 9.0 27270804 ECl@ss 10.0 27270804 ECl@ss 11.0 27270804 ECl@ss 12.0 27272806 ETIM 5.0 EC001846 ETIM 6.0 EC001846 ETIM 7.0 EC001846 ETIM 8.0 EC001846 UNSPSC 16.0901 41111960